Error Possible causes Remedy
Implausible measured
values
Implausible measured values often occur
due to inappropriate handling of the
device or mistakes during the measuring
procedure.
Please refer to Chapter 5 ‘Measuring
your blood pressure’ as well as the
safety information. Then repeat the
measurement.
• Switch the device off if an error symbol appears. Check for all possible causes and follow the 10 golden rules
(Chapter 5 ´Measuring your blood pressure`) as well as the instructions for self-measurement from Chapter 2
‘Important information’.
• Relax for one minute and then take the measurement again.
9. Monitor maintenance
• Only use a soft, damp cloth to clean the device. Please do not use thinner, alcohol, detergents or solvents.
• The cuff can be cleaned carefully using a slightly damp cloth and mild soap solution. Do not completely immerse the
cuff in water.
• It is recommended to clean and disinfect the cuff regularly or after each use, especially when used by several users,
to prevent infection. The cuff should be disinfected, particularly on the inside, by wiping with a disinfectant. Use
a disinfectant that is compatible with the cuff materials, e.g. 75 % ethanol or isopropyl alcohol. To protect from
external influences, keep the device, the cuff and these instructions in the storage bag.
• If you store a device and cuff, do not place any heavy objects on the device and the cuff. Remove the batteries.
10. Accessories
• To ensure the accuracy of the measurement, please use only original accessories from HARTMANN, such as the
Veroval®
power supply unit (model number: 925 391), which can be ordered from your pharmacist or medical
specialist.
• Mains power mode: On the back of the unit is a connector socket for the adapter for mains operation
(output 6V DC/600 mA). Only use the
Veroval®
power supply unit. The warranty covering the function and measuring
accuracy of the monitor cannot be assumed otherwise.
• For more information, please visit www.veroval.info.
11. Warranty conditions
• We offer a 3-year warranty for this high-quality blood pressure monitor from the purchase date and in accordance
with the conditions listed below.
• Warranty claims must be made during the warranty period. The purchase date must be documented by an
appropriately completed and stamped warranty certificate or proof of purchase.
• Within the warranty period, HARTMANN will replace or repair free of charge any faulty device components caused by
material faults or manufacturing errors. This does not extend the warranty period.
• For local warranty conditions, please consult the local warranty certificate.
• This device is solely intended for the purpose stated in these instructions for use.
• The manufacturer is not liable for damage or injuries resulting from improper handling, use or unauthorized
interference. Accessory parts that are subject to wear and tear (batteries, cuffs, etc.) are excluded from the warranty.
Claims for compensation are limited to the value of the product; compensation for consequential damage or injury is
expressly excluded.
• In warranty cases, please send the monitor with cuff and, if applicable, the power supply unit, together with the fully
completed and stamped warranty certificate or purchase receipt directly or via your dealer to the Customer Services
department of your country.
12. Contact information for customer enquiries
ZA – HARTMANN South Africa
Epsom Avenue, Northriding,
2169 Johannesburg
www.veroval.info
Tel. +27 860 4278 6266
phzahelpdesk@hartmann.info
If necessary, please contact us at the relevant address listed at the end of the instructions for any questions regarding
initial startup, use and maintenance of the device, or to report an unexpected operating malfunction or incident. For
a patient/user/third party in the European Union and in countries with identical regulatory regime (Regulation (EU)
2017/745 on Medical Devices); if, during the use of this device or as a result of its use, a serious incident has occurred,
please report it to the manufacturer and/or its authorized representative and to your national authority.
Vigilance contact point for Europe: www.ec.europa.eu/growth/sectors/medical-devices/contacts/
13. Technical data
Model Veroval® BPU 26
Type GCE609
Measuring method Oscillometric
Display range 0–300 mmHg
Measuring range Systolic (SYS): 50–280 mmHg
Diastolic (DIA): 30–200 mmHg
Pulse: 40–199 pulse beats per minute
Displaying of correct values outside the measuring range cannot be guaranteed.
Display unit 1 mmHg
Technical measurement
accuracy
Cuff pressure: ±3 mmHg
Pulse: ±5 % of the displayed pulse rate
Clinical measuring
accuracy
Complies with the requirements of IEC 80601-2-30;
Korotkoff validation method: Phase I (SYS), Phase V (DIA)
Operating mode Continuous mode
Nominal voltage DC 6V
Power supply 4 x 1.5 V alkaline manganese (AA/LR06) batteries or optional Veroval® power
supply unit
Expected service life 20,000 measurements
Battery capacity Approx. 800 measurements
Protection against electric
shock
Medical-electrical equipment with internal power supply (only when batteries are
used); applied part: type BF
Protection against harmful
ingress of water or solid
materials
IP21
Inflation pressure Comfort Air Technology:
Individual inflation pressure depends on systolic blood pressure
Automatic switch-off function 2 minutes after measurement/otherwise 30 sec.
Cuff Veroval® cuff for BPU 26, cuff for arm circumference of 22 to 42 cm
Model number: 30602
Memory capacity 2 × 100 measurements with average of all measurements and morning/evening
average of the last 7 days
Operating conditions Ambient temperature: +10 °C to +40 °C
Relative humidity: <90 %, non-condensing
Air pressure: 800 hPa – 1050 hPa
Storage/transport
conditions
Ambient temperature: –20 °C to +55 °C
Relative humidity: <90 %, non-condensing
Serial number On the rating label
Reference to standards IEC 60601-1; IEC 60601-1-2 (In accordance with CISPR11,
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-8)
Weight Approx. 220 g (without batteries)
Dimensions 134(L) x 91(W) x 48(H) mm
Data transfer 2400 MHz - 2483.5 MHz frequency band
Transmission power: +5 dBm
The blood pressure monitor used Bluetooth® low energy technology compatible
with Bluetooth® ≥ 4.0 smartphones/tablets
Power supply unit:
Model no. LXCP12-006060BEH
Input 100–240V~, 50–60Hz, 0.5A max
Output 6V DC, 600mA
Manufacturer Globalcare Medical Technology Co., Ltd.
Protection The device is double-insulated and has a primary fuse which disconnects the
monitor from the mains in the event of a fault. Make sure you have removed the
batteries from the battery compartment before connecting the power supply
unit.
Polarity of the DC voltage connection
Protective insulation / Protection Class 2
Housing and protective covers The power supply unit housing protects against touching parts that can carry a
current (fingers, needles, test hooks). The user must not touch the patient and the
outlet plug of the AC / DC power supply unit at the same time.
Legal requirements and guidelines
• The Veroval® BPU 26 conforms with the Regulation (EU) 2017/745 of the European Parliament and of the Council on
medical devices, as well as the respective national provisions, and bears the CE mark.
• The device complies with international standard IEC 80601-2-30 (Medical electrical equipment Part 2-30: Particular
requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers).
• This product is subject to special precautionary measures with regard to electromagnetic compatibility.
• Beyond statutory requirements, the device has been clinically validated by the ESH-IP2 Protocol of the European
Society of Hypertension (ESH) and the protocol of the German society of hypertension (DHL).
• We hereby confirm that this product complies with the European RED Directive 2014/53/EU. The CE Declaration of
Conformity for this product can be found under: www.veroval.info
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth® SIG, Inc. and any use of such marks
by PAUL HARTMANN AG is under license. Other trademarks and trade names are those of their respective owners.
Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service
mark of Apple Inc., registered in the U.S. and other countries.
Google Play and the Google Play logo are trademarks of Google LLC.
Android is a trademark of Google LLC.
Date of revision of the text: 2022-08-11, Version 1
Subject to errors and changes
Upper arm blood pressure monitor
Purchase date
Serial number (see rating label)
Reason for complain
Dealer‘s stamp
Globalcare Medical Technology Co., Ltd.
7th Building, 39 Middle Industrial Main Road
European Industrial Zone, Xiaolan Town
528415 Zhongshan City, Guangdong Province, P.R.C.
www.globalcare.com.hk
Beurer GmbH
Söflinger Str. 218
89077 Ulm, Germany
Camara and Partners Sàrl
Route de St Cergue 14
1260 Nyon, Switzerland
Donawa Lifescience
Piazza Albania, 10
00153 Rome, Italy
www.donawa.com
925106/0 (240822)
Warranty certificateVeroval
®
BPU 26
IFU_9251060_240822.indd 2
IFU_9251060_240822.indd 2
25.08.22 15:09
25.08.22 15:09

使用 AI 与您的 Hartmann Veroval compact+ BPU26 手册聊天

从您的 Hartmann Veroval compact+ BPU26 手册中获取即时 AI 答案

询问有关 Hartmann Veroval compact+ BPU26 的任何问题。答案来自本手册及其所依据的页面。

Veroval compact+ BPU26 维护计划

维护到期时提醒我
每2年
进行计量检查

对于专业用途的设备(例如药房、医院),请每2年由授权机构进行一次计量检查,以确保测量准确性。

在手册中显示 (第 1 页)
定期或每次使用后
清洁并消毒袖带

定期或在每次使用袖带后对其进行清洁和消毒,尤其是当袖带被多人共用时。请使用略微湿润的布配合温和肥皂或兼容的消毒剂(如75%乙醇)进行清洁。

在手册中显示 (第 2 页)
按需
更换电池

当电池图标持续亮起或显示“LO”时,请同时更换全部四节电池。请立即取出电量耗尽的电池,以防止漏液。

在手册中显示 (第 1 页)

免费维护提醒

根据您的购买日期确定提醒时间。始终免费,随时可取消订阅。

提交即表示您同意隐私政策。您可以在任何邮件中一键取消订阅。
M: qwen/qwen3.8-flash

提问 问题

0/1000

您会推荐 Veroval compact+ BPU26 吗?

是 否

常见问题 问题

A

是的,该监视器不影响起搏器。但是,它可能会导致异常值。显示的脉搏率不适合检查起搏器频率。自行测量前请咨询您的医生。

此回答有帮助吗?

A

为了进行有意义的评估,请在每天相同的时间进行测量,持续较长时间。定期监测有助于识别趋势。请与您的医生讨论适当的日程安排。

此回答有帮助吗?

A

绿色表示最佳或正常血压。黄色提示一级高血压。橙色表示二级高血压。红色表示三级高血压。这些与世界卫生组织 (WHO) 和欧洲心脏病学会/欧洲高血压学会 (ESC/ESH) 指南一致。

此回答有帮助吗?

A

是的,它通过蓝牙连接到 iOS 10+ 或 Android 5.0+ 设备上的 Veroval medi.connect 应用程序。您可以轻松查看图表并与医生共享数据。

此回答有帮助吗?

A

查阅手册以获取特定代码,如 E1(脉搏问题)或 E3(袖带贴合)。通常,休息一分钟并正确重新佩戴袖带即可解决问题。如果是系统错误,请联系支持部门。

此回答有帮助吗?

A

是的,通用袖带适合 22 厘米至 42 厘米的手臂周长。确保袖带上的白色箭头指向刻度尺内,以获得准确的测量结果。

此回答有帮助吗?

M: QW-35-FL

優勢 和 劣勢

优势

  • Comfort Air 技术可调整充气压力,提供更舒适的测量体验。
  • 双用户存储可为两个人各存储 100 次读数,并附带日期和时间戳。
  • 蓝牙连接允许自动将数据传输到 Veroval medi.connect 应用程序,以便轻松跟踪。
  • 交通灯系统提供关于血压分类的即时视觉反馈。
  • 检测不规则心跳和心房颤动,以提醒用户潜在的的心脏问题。
VS

缺点

  • 不适用于婴儿、新生儿或手臂尺寸在 22-42 厘米范围之外的人群。
  • 如果用户患有严重心律失常或在测量期间移动,读数可能不准确。
  • 设备不防水,必须远离湿气和极端温度。
  • 需要定期更换电池或购买特定的电源装置以确保持续使用。
  • 不能用于诊断医疗状况;解释时始终需要咨询医生。
M: QW-35-FL

产品 规格

Betriebsart

Batteriebetrieben (4x AA-Batterie)

Messbereich

Oberarm, vollautomatisch

Manschettenmaß

22-42 cm

Analyse-Daten

Systole, Diastole, Puls, Arrhythmieerkennung, Risikohinweis, Ruhehinweis

Speicherfunktion

Benutzerspeicher (für 2 Personen) mit je 100 Plätzen

Anzeige

Ja

Funktionen

Datumsanzeige, Zeitanzeige, automatische Vorpressung, Batteriestandsanzeige, Durchschnittswertanzeige, automatisches Ausschalten nach 2 Minuten

Smart Home

App-Steuerung optional (Bluetooth, medi.connect)

Lieferumfang

Tasche, 4x Batterien

M: QW-35-FL

产品 描述

使用 Hartmann Veroval compact+ BPU26 掌控您的心脏健康

管理您的血压是实现长期健康的重要一步,而 Hartmann Veroval compact+ BPU26 上臂血压计手册使这一过程变得简单、准确且可靠。该设备专为家庭和临床使用设计,赋予成年人自信地追踪心血管健康的能力。无论您是在监测高血压还是仅维持日常健康,此设备都能提供所需的精度,无需复杂的设置。

Hartmann Veroval compact+ BPU26 采用创新的 Comfort Air 技术,可根据您的个人收缩压自动调整充气压力。这确保了舒适的测量体验,同时提供一致的结果。大 LCD 显示屏清晰显示收缩压和舒张压读数以及脉搏率,即使对于视力受损者也易于阅读。屏幕左侧独特的交通灯系统根据世界卫生组织 (WHO) 和欧洲心脏病学会/欧洲高血压学会 (ESC/ESH) 指南,将您的结果即时分类为最佳、正常、高正常或高血压等级。

该监视器最突出的功能之一是其双用户存储容量。它可以存储多达 100 次测量记录供两个独立用户使用,并附带日期和时间戳。这使得家庭能够轻松维护个人的健康记录。该设备还会计算过去七天的早晨和晚上平均值,为医生提供有价值的趋势数据,而非孤立的数据点。对于偏好数字集成的用户,内置的蓝牙连接可将数据无缝传输到 iOS 或 Android 设备上的 Veroval medi.connect 应用程序。该应用程序允许您可视化趋势、生成图表,并通过电子邮件直接将报告分享给您的医疗保健提供者。

安全是医疗设备的首要任务,Hartmann Veroval compact+ BPU26 包括对不规则心跳和心房颤动的先进检测。如果在测量期间检测到此类情况,显示屏上会出现特定符号,提示您咨询医生。然而,必须记住,这些读数仅供参考,绝不能替代专业的医疗建议或诊断。在更改任何药物或治疗计划之前,务必与医生讨论您的测量值。

重要提示

  • 不要在新生儿、婴儿或幼儿身上使用此设备。
  • 避免在进食、饮用含咖啡因饮料或运动后立即测量。
  • 确保袖带正确佩戴,袖带与手臂之间应能容纳两根手指,以确保结果准确。
  • 一旦低电量符号出现,请立即更换电池,以防止读数不准确。